SMARTGEN E12K-SL-S
Single-phase hybrid inverter, 51.2 V low-voltage battery
Specifications
| Rated output power | 12 kW |
|---|---|
| Peak power | 16 kW – 10 s (BAT+PV) |
| Rated output current | 52.2 A |
| Rated grid voltage | 230 V |
| Grid voltage range | 184–276 V |
| Frequency | 50/60 Hz |
| Generator input current | 80 A |
| Max. PV power | 24000 Wp |
| PV start voltage | 95 V |
| Max. PV voltage | 500 V |
| MPPT voltage range | 80–500 V |
| MPPT count / strings per MPPT | 2 / 2 |
| Max. PV current | 36 A / 36 A |
| PV short-circuit current | 44 A / 44 A |
| Battery type | Lithium-ion / Lead-acid / Sodium-ion |
| Rated battery voltage | 51.2 V |
| Battery voltage range | 30–60 V |
| Max. charge & discharge current | 240 A |
| Max. efficiency | 97.9% |
| Euro efficiency | 97.8% |
| Max. charge/discharge efficiency | 94% |
| Dimensions (W×H×D) | 400 × 528 × 244 mm |
| Weight | 29.5 kg |
| Noise | < 45 dB(A) |
| Operating temp. | -25 ~ +60 ℃ (derating 40–55 ℃) |
| Altitude | ≤ 4000 m |
| Ingress protection | IP65 |
| Units in parallel (off-grid) | 6 |
| Monitoring | LCD / APP / WiFi / Bluetooth / 4G / LAN |
| Communication Ports | RS485 / CAN / DO / Parallel port |
| Phase | Single phase, low-voltage battery, on/off-grid hybrid |
Certifications
CE-LVDCE-EMC
Standards: IEC 62109-1, IEC 62109-2, EN 62109-1, EN 62109-2, IEC 62477-1, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 62920
Protection: DC switch; AC overvoltage/overcurrent/short-circuit protection; anti-islanding; residual current monitoring; surge protection level II; PV & battery reverse polarity protection.